  specifications and/or agency recognitions do not necessarily apply to all models within a particular series. when multiple rat ings are listed, no individual rating may be exceeded by the combination of others. vii dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. selector guide catalog 1308242 issued 3-03 transformers series type va rating terminal options mounting options agency approval page number 4000 class ii ul1585 transformer inherently energy limited 5, 10, 20 & 30va wire leads foot or panel 204 products unlimited 4000 class ii ul1585 transformer inherently energy limited 10, 20 & 30va quick connect foot or panel 205 products unlimited 4000 class ii ul1585 transformer inherently energy limited 20 & 40va wire leads & screws plate 206 products unlimited 4000 class ii ul1585 transformer inherently energy limited 40 & 50va wire leads foot or panel 207 products unlimited 4000 class ii ul1585 transformer inherently energy limited 40 & 50va quick connect foot or panel 208 products unlimited transformers series type va rating terminal options mounting options agency approval page number 4000 class ii ul1585 transformer non-inherently energy limited secondary fusing required (opt. integral fuse or breaker) 60 & 75va wire leads foot or panel 209 products unlimited 4000 class ii ul1585 transformer non-inherently energy limited secondary fusing required (opt. integral fuse or breaker) 60 & 75va quick connect foot or panel 210 products unlimited 4700 ul506 transformer non-fused 60, 100 & 150va wire leads foot 211 products unlimited 4700 ul506 transformer non-fused 60, 100 & 150va quick connect foot 211 products unlimited 57 transformer relay inherently energy limited 9100 or 9400 series relay 40va wire leads and screws (optional quick connects) plate 212 products unlimited click here for alphanumeric index
201 dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. transformers catalog 1308242 issued 3-03 circuit breakers ........................ 101-124 transformers ........................... 201-212 low-signal pc board relays .......... 5-18 mid-range pc board relays ....... 19-21 power pc board relays ................ 22-35 relays with forcibly-guided contacts.............. 36-79 plug-in/panel mount general purpose relays................ 80-88 power relays & definite purpose contactors...................... 89-131 latching, impulse & rotary relays ............................... 149-154 automotive relays ...................... 141-148 solid state relays & input/output modules ................ 195-207 time delay relays & counters ........................................ 208-232 sensors & monitors ................... 233-234 high performance relays and contactors (overview) ....... 233-234 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4000 ................... 5-30va, wire leads, class ii ................... 204 4000 ................... 10-30va, qc terminals, class ii ............. 205 4000 ................... 20-40va, plate mount, class ii ................ 206 4000 ................... 40-50va, wire leads, class ii ................. 207 4000 ................... 40-50va, qc terminals, class ii ............. 208 4000 ................... 60-75va, wire leads, class ii ................. 209 4000 ................... 60-75va, qc terminals, class ii ............. 210 4700 ................... 60-150va, wire leads or qc, ul 508 .... 211 57 ....................... transformer relay for hvac ................... 212 series type page alphanumeric index transformers........ custom capabilities........................................203 transformers........ questions and answers..................................202
products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 (pdf rev, 8-05) specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. what is a transformer? a transformer is a passive electrical device which is designed to change one ac voltage to another by magnetic induction. it steps-up?or ?teps-down voltage in order to match incoming supply voltage from the utility to the voltage required by the users end product. typical usa supply voltages are 120, 208, 240, 277, 480 (and 575 in canada). common international voltages include 110, 220, 380, and 415. what is an isolation transformer? an isolation transformer is a transformer whose primary and secondary windings are separate for the purpose of isolating the ci rcuit from the supply source. what is an autotransformer? an autotransformer has only one winding, which is shared by the primary and secondary circuits. autotransformers do not provid e isolation but offer a substantial savings when used to obtain small increments of voltage above or below the input voltage. what is a class ii transformer? a class ii transformer is used to supply class ii circuits. class ii transformers have a maximum va (volt-ampere) rating of less than 100 and a maximum secondary output of 30 vac. the maximum va generally offered is 75 and the most common secondary voltage is 24 vac. no load se condary voltage may be as high as 29 vac. all class ii transformers are either inherently or non-inherently limited. this means that the maximum o utput current of the transformer is limited, either by the intrinsic coil impedance or by a fuse or circuit breaker. these transformers are designed to meet the requirements of u.l. 1585. inherently energy limited transformers - class ii transformers up to 50 va are ?nherently limited?which means that the transf ormer, if overloaded, will short itself out and fail safely, not requiring a fuse . non-inherently energy limited transformers - 60 thru 75 va class ii transformers are generally protected by a resettable circuit breaker or a fuse within the transformer secondary. without this overload protection, the transformer would not satisfy the safety requirements for a class ii circuit. what is a general purpose transformer? general purpose transformers include any va rating along with primary and secondary voltage ratings up to 600 vac. although internal fusing is an option, no fusing is required. however, applicable u.l. specifications may require fusing in the end product. these transformers are designed to meet the requirements of u.l. 506. what is voltage regulation? voltage regulation is the percent of change in the output voltage when the load is reduced from full load to no load while the input voltage remains constant. what is the effect of a load on a control transformer? a control transformer is designed to provide rated output voltage at full va. as the load decreases, the output voltage will g o up. conversely, increases in load will result in lower output voltages. typically, the smaller the va size of the unit, the greater difference there is bet ween no-load and full-load voltage. transformers ...questions and answers part numbering system typical part no. b 4000 01 e 07 bb 999 1. series: 4000 = class ii (ul 1585) inherently protected or internally fused. 4500 = autotransformer. 4001 = class ii (ul 1585) externally fused. 4600 = 60 hz. only 4100 = no ul or csa approval. 4700 = general purpose (ul 506). 2. packaging: ?= bulk pack y = individual box 3. primary and secondary voltages: primary v secondary v primary v secondary v 01 = 120 24 09 = 208/240 24 02 = 240 24 13 = 208/240/480 24 03 = 277 24 20 = 120 12 04 = 480 24 51 = 380/415 24 05 = 120/208/240 24 78 = 575 24 4. va and series dimension: va rating series size va rating series size a = 10 3/4?(19.05mm) aw = 50 7/8?(22.22 mm) c = 20 3/4?(19.05mm) l = 60 15/16?(23.81mm) m = 30 3/4?(19.05mm) j = 75 15/16?(23.81mm) e = 40 7/8?(22.22 mm) k = 100 1 1/4?(31.75mm) v = 40 3/4?(19.05mm) z = 150 1 1/4?(31.75mm) 5. stack thickness and fusing (generally determined at factory): 19 = 0.5?(12.7mm) thick. 07 = 0.875?(22.225mm) thick. 15 = 1.00?(25.4mm) thick. 02 = 0.625?(15.875mm) thick. 04 = 1.00?(25.4mm) thick. 18 = 1.25?(31.75mm) thick. 6. mounting and termination: mounting termination mounting termination k = foot mount leads ae = foot mount qcs on top bc = 4?(101.6mm)foot screw / leads bb = foot mount qcs on one side g = panel mount leads ab = foot mount qcs on other side 7. customer id suffix: 000-999 = factory assigned customer id example: 4000-01e07bb999 this part number is a class ii transformer with a 120v primary and 24v secondary. it is 40va and inh erently energy limited. this is a foot mount transformer with quick connect terminals (line & load) exiting out of the same side of the transformer cover. note: this is a partial listing only. consult factory for your specific requirements. all combinations of voltage and va may no t be available. this chart illustrates a breakdown of our part numbering system on a few of our most popular models. consult factory for your s pecific requirements.
203 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. custom transformer capabilities in addition to our industry leading standard transformer series (see the following pages), we have a proven track record of bei ng an innovative leader in custom transformer designs. we specialize in working with our customers in the initial stages of their design process, offerin g ideas and suggestions which lead to a transformer product that can be manufactured with the lowest defective parts per million (dppm) levels and at the highest value to the customer. the following is a list of guidelines for transformer products which compliment our demand flow manufacturing system. leaded transformers - quick connect transformers - pc mount transformers - inductors 5 va through 400 va spray on rust preventative butt stack and weld lamination construction molded bobbin construction numerous welded bracket options molded cover with integral strain relief for lead or quick connect terminal when a transformer fits the above criteria and the customer is willing to share in the design process with us, we can both bene fit from design for manufacturing (dfm) , as demonstrated in the following example: traditional method dfm method ? dppm level >2000 ? dppm level <100 ?10 week lead time ? 1 week lead time ? 3 part numbers ? 1 universal part number ? 12 inventory turns ? 50 inventory turns ? costly ? 20% cost improvement ? fragile design ? robust design our electrical and mechanical design groups are ready to work with you on your specific product needs.
204 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type k foot mount - features a steel bracket welded to the bottom of the laminations for easy mounting. ?type g panel mount - features .179?(4.55 mm) diameter holes in each corner to allow direct mounting to a panel. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications wire size: all leads are 18 awg stranded 2/64?(.794 mm) insulation thickness. standard parts have 12?(305 mm) total length with 1/2?(12.7 mm) strip. frequency: 50/60 hz. insulation class: ul class b (130?). weight: 5va ?10.56 oz. (300 g); 10va ?10.88 oz. (308 g); 20va ?14.24 oz. (404 g); 30va ?19.2 oz. (544 g). 4000 series class ii ul 1585 transformer 5 va - 30va inherently energy limited no secondary fusing required wire leads file e87824 outline dimensions 1.55 (39.37) .187 dia (4.75) 2.812 (71.42) see table 1.88 (47.75) a?dim. 03 (.76) .22 (5.59) .750 (19.05) 2.25 (57.15) 1.25 (31.75) 1.55 (39.37) 1.88 (47.75) 1.25 (31.75) ??dim. a?dim. see table .218 (5.54) .179 dia typ (4.55) 1.50 (38.1) primary leads secondary leads voltage com 120 208 240 277 480 575 24 vac color black white red orange brown black/red gray blue yellow length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) strip length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 5 va 10 va 20 va 30 va a?dimension [inches (mm)] 1.5 (38.1) 1.5 (38.1) 1.625 (41.28) 2.00 (50.8) ??dimension [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.625 (15.9) 1.00 (25.4) type k foot mount type g panel mount details regarding leads on standard models a and b dimensions primary v secondary v 20va 120 24 4000-01c02k999 120 24 4000-01c02k999 primary v secondary v 5va 10va 20va 30va 120 24 4000-01x19k* 4000-01a19k* 4000-01c02k* 4000-01m04k* 240 24 4000-02x19k* 4000-02a19k* 4000-02c02k* 4000-02m04k* 277 24 4000-03x19k* 4000-03a19k* 4000-03c02k* 4000-03m04k* 480 24 4000-04x19k* 4000-04a19k* 4000-04c02k* 4000-04m04k* 208/240 24 4000-09c02k* 4000-09m04k* 120 12 4000-20c02k* standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. all custom model part numbers are listed as type k foot mount. to specify type g panel mount, replace k in above part numbers with g. for more details about standard models see part numbering system table at beginning of transformer section in this catalog .
205 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type bb same side termination - features quick connect terminals with line and load terminations on the same side of transformer. ?type ae laydown termination - features quick connect terminals with line and load terminations on the top of transformer. ?type ab opposite side termination - features quick connect terminals with line and load terminations on opposite sides of transformer. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications terminals: standard male quick connects are .250?x .032?(6.35 x .81 mm). other available quick connects include .187?x .032 (4.75 x .81 mm) and .187?x .020?(4.75 x .51 mm). frequency: 50/60 hz. insulation class: ul class b (130?). weight: 10va ?10.9 oz. (308 g); 20va ?14.1 oz. (399 g); 30va ?18.6 oz. (525 g). 4000 series class ii ul 1585 transformer 10va - 30va inherently energy limited no secondary fusing required quick connect terminals file e87824 outline dimensions no standard models are offered. primary v secondary v 10va 20va 30va 30va 120 24 4000-01a19bb* 4000-01c02bb* 4000-01m04bb* 4000-01m04bb* 240 24 4000-02a19bb* 4000-02c02bb* 4000-02m04bb* 4000-02m04bb* 277 24 4000-03m04bb* 4000-03m04bb* 480 24 4000-04m04bb* 4000-04m04bb* 208/240 24 4000-09m04bb* 4000-09m04bb* 120 12 4000-20c02bb* standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. to specify type ae laydown termination, replace bb in above part numbers with ae. for more details about standard models see part numbering system table at beginning of transformer section in this catalog . .187 dia (4.75) 2.812 (71.42) a?dim. .031 (.787) .22 (5.59) .750 (19.05) ??dim. a?dim. .187 dia (4.75) 10va 20va 30va a?dimension [inches (mm)] 1.50 (38.1) 1.625 (41.28) 2.00 (50.8) ??dimension [inches (mm)] .50 (12.7) 0.625 (15.88) 1.00 (25.4) type bb same side termination type ae laydown termination a and b dimensions 2.25 (57.15) 1.60 (40.6) 1.40 (35.56) ??dim. a?dim. type ab opposite side termination 1.88 (47.75) ??dim. 1.40 (35.56) 1. 0 (2.54) r .375 (9.53) .048 (1.22) 1.40 (35.56) .187 dia (4.75) .031 (.787) .22 (5.59) .750 (19.05) 1.55 (39.4) r .375 (9.53) 1.60 (40.6) 2.812 (71.42) 2.25 (57.15) 1.88 (47.75) 2.25 (57.15) 1.88 (47.75) 2.812 (71.42)
206 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type bc plate mount - mounted on a 4?(101.6mm) square plate designed to fit a standard 4?(101.6mm) square electrical box. ?the line voltage is connected inside the electrical boxto the color-coded leads on the transformer. the low voltage is terminated to either 1/4 (4.75 mm) quick connects and/or #6-32 screw furnished on the secondary side. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications wire size: all leads are 18 awg stranded 2/64?(.794 mm) insulation thickness. standard parts have 12?(305 mm) total length with 1/2?(12.7 mm) strip. frequency: 50/60 hz. insulation class: ul class b (130?). weight: 20va ?19.2 oz. (544 g); 40va ?32 oz. (906 g). 4000 series class ii ul 1585 transformer 20va - 40va inherently energy limited no secondary fusing required plate for electrical box mounting file e87824 outline dimensions 1.55 (39.37) 3.375 (85.72) 1.88 (47.75) a?dim. .22 (5.59) 2.25 (57.15) 1.25 (31.75) 1.1 8 7 (30.15) 1. 0 0 (25.4) ??dim. .50 (12.7) primary leads secondary leads voltage com 120 208 240 277 480 575 24 vac color black white red orange brown black/red gray blue yellow length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) strip length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) details regarding leads on standard models primary v secondary v 20va 40va 120 24 4000-01c02bc999 4000-01v18bc999 primary v secondary v 20va 40va 120 24 4000-01c02bc* 4000-01v18bc* 208/240 24 4000-09c02bc* 4000-09v18bc* standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. all custom model part numbers are listed as type k foot mount. to specify type g panel mount, replace k in above part numbers with g. for more details about standard models see part numbering system table at beginning of transformer section in this catalog . .18 7 (4.75) .18 7 (4.75) 3.375 (85.72) 4.25 (108) 4.25 (108) 20 va 40 va a?dimension [inches (mm)] 1.625 (41.28) 2.56 (65.02) ??dimension [inches (mm)] .625 (15.88) 1.25 (31.75) a and b dimensions
207 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type k foot mount - features a steel bracket welded to the bottom of the laminations for easy mounting. ?type g panel mount - features .156?(3.96 mm) diameter holes in each corner to allow direct mounting to a panel. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications wire size: all leads are 18 awg stranded 2/64?(.794 mm) insulation thickness. standard parts have 12?(305 mm) total length with 1/2?(12.7 mm) strip. frequency: 50/60 hz. insulation class: ul class b (130?). weight: 40va ?24.3 oz. (600 g); 50va ?33.6 oz. (953 g). 4000 series class ii ul 1585 transformer 40 va - 50va inherently energy limited no secondary fusing required wire leads file e87824 outline dimensions primary leads secondary leads voltage com 120 208 240 277 480 575 24 vac color black white red orange brown black/red gray blue yellow length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) strip length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) details regarding leads on standard models primary v secondary v 40va 50va 120 24 4000-01e07k999 4000-01aw18k999 277 24 4000-03e07k999 4000-03aw18k999 480 24 4000-04e07k999 4000-04aw18k999 120/208/240 24 4000-05e07k999 208/240 24 4000-09e07k999 4000-09aw18k999 primary v secondary v 40va 40va 50va 120 24 4000-01v18k* 4000-01e07k* 4000-01aw18k* 240 24 4000-02v18k* 4000-02e07k* 4000-02aw18k* 277 24 4000-03v18k* 4000-03e07k* 4000-03aw18k* 480 24 4000-04v18k* 4000-04e07k* 4000-04aw18k* 120/208/240 24 4000-05e07k* 208/240 24 4000-09v18k* 4000-09e07k* 4000-09aw18k* 208/240/480 24 4000-13e07k* 380/415 24 4000-51v18k* 4000-51e07k* 4000-51aw18k* 575 24 4000-78v18k* 4000-78e07k* 4000-78aw18k* standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. all custom model part numbers are listed as type k foot mount. to specify type g panel mount, replace k in above part numbers with g. for more details about standard models see part numbering system table at beginning of transformer section in this catalog . [1] 1.55 (39.37) [2] 1.813 (46.05) .187 dia (4.75) [1] 2.812 (71.42) [2] 3.125 (79.38) see table a?dim. 03 (.76) .22 (5.59) .750 (19.05) [1] 1.25 (31.75) [2] 1.44 (36.58) ??dim. a?dim. see table .218 (5.54) .156 dia typ (3.96) [1] 1.50 (38.1) [2] 1.75 (44.45) 40 va / v18 40 va / e07 50 va / aw18 a?dimension [inches (mm)] 2.25 (57.15) 2.125 (53.98) 2.56 (65.02) ??dimension [inches (mm)] 1.25 (31.75) 0.875 (22.22) 1.25 (31.75) type k foot mount type g panel mount a and b dimensions [1] 2.25 (57.15) [2] 2.625 (66.68) [1] 1.88 (47.75) [2] 2.188 (55.58) [1] 1.55 (39.37) [2] 1.813 (46.05) [1] 1.88 (47.75) [2] 2.188 (55.58) [1] 1.25 (31.75) [2] 1.44 (36.58) [1] applies to v18 models. [2] applies to e07 & aw18 models.
208 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type bb same side termination - features quick connect terminals with line and load terminations on the same side of transformer. ?type ae laydown termination - features quick connect terminals with line and load terminations on the top of transformer. ?type ab opposite side termination - features quick connect terminals with line and load terminations on opposite sides of transformer. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications terminals: standard male quick connects are .250?x .032?(6.35 x .81 mm). other available quick connects include .187?x .032 (4.75 x .81 mm) and .187?x .020?(4.75 x .51 mm). frequency: 50/60 hz. insulation class: ul class b (130?). weight: 40va ?22.4 oz. (636 g); 50va ?35.2 oz. (999 g). 4000 series class ii ul 1585 transformer 40va - 50va inherently energy limited no secondary fusing required quick connect terminals file e87824 outline dimensions primary v secondary v 40va 120 24 4000-01e07ae999 120 24 4000-01e07bb999 208/240 24 4000-09e07ae999 primary v secondary v 40va 40va 40va 50va 120 24 4000-01e07bb* 4000-01v18bb* 4000-01v18ab* 4000-01aw18bb* 240 24 4000-02e07bb* 4000-02v18bb* 4000-02v18ab* 4000-02aw18bb* 277 24 4000-03e07bb* 4000-03v18bb* 4000-03v18ab* 4000-03aw18bb* 480 24 4000-04e07bb* 4000-04v18bb* 4000-04v18ab* 4000-04aw18bb* 208/240 24 4000-09e07bb* 4000-09v18bb* 4000-09v18ab* 4000-09aw18bb* 380/415 24 4000-51e07bb* 4000-51v18bb* 4000-51v18ab* 4000-51aw18bb* 575 24 4000-78e07bb* 4000-78v18bb* 4000-78aw18bb* standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. to specify type ae laydown termination, replace bb in above part numbers with ae. for more details about standard models see part numbering system table at beginning of transformer section in this catalog . .187 dia (4.75) [1] 2.25 (57.15) [2] 3.125 (79.38) a?dim. .031 (.787) .22 (5.59) .750 (19.05) ??dim. a?dim. .187 dia (4.75) [1] 2.812 (71.42) [2] 3.125 (79.38) 40 va / v18 40 va / e07 50 va / aw18 a?dimension [inches (mm)] 2.25 (57.15) 2.125 (53.98) 2.56 (65.02) ??dimension [inches (mm)] 1.25 (31.75) 0.875 (22.22) 1.25 (31.75) type bb same side termination type ae laydown termination a and b dimensions [1] 2.25 (57.15) [2] 2.625 (66.68) [1] 1.50 (38.1) [2] 1.81 (45.97) [1] 1.40 (35.56) [2] 1.494 (37.95) [1] applies to v18 models. [2] applies to e07 & aw18 models. ??dim. a?dim. type ab opposite side termination [1] 1.88 (47.75) [2] 2.188 (55.58) [1] 1.88 (47.75) [2] 2.188 (55.58) ??dim. [1] 1.40 (35.56) [2] 1.494 (37.95) 1. 0 (2.54) r .375 (9.53) [1] 2.25 (57.15) [2] 2.625 (66.68) [1] 1.50 (38.1) [2] 1.81 (45.97) .048 (1.22) 1.40 (35.56) [1] 2.25 (57.15) [2] 2.625 (66.68) .187 dia (4.75) .031 (.787) .22 (5.59) .750 (19.05) 1.55 (39.4) [1] 2.812 (71.42) [2] 3.125 (79.38) r .375 (9.53) 1.88 (47.75)
209 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type k foot mount - features a steel bracket welded to the bottom of the laminations for easy mounting. ?type g panel mount - features .218?(5.54 mm) diameter holes in each corner to allow direct mounting to a panel. ?for agency approval, 60 & 75va transformers must have one of the following overcurrent protectors in series with the secondary winding: internal fuse, integral circuit breaker. any customer-supplied fusing or protection must be approved by the factory. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications wire size: all leads are 18 awg stranded 2/64?(.794 mm) insulation thickness. standard parts have 12?(305 mm) total length with 1/2?(12.7 mm) strip. frequency: 50/60 hz. insulation class: ul class b (130?). weight: 60va ?35.2 oz. (997 g); 75va ?38.4 oz. (1087 g). 4000 series class ii ul 1585 transformer 60va -75va non-inherently energy limited secondary fusing required wire leads file e87824 outline dimensions standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. for type g panel mount, replace k in above part numbers with g. for more details about standard models see part numbering system table at beginning of transformer section in this catalog . all 75va standard models come with an integral circuit breaker. .187 dia (4.75) 3.562 (90.47) a?dim. .062 (1.57) .22 (5.59) .750 (19.05) ??dim. a?dim. l15k & j15k l15k & j15k j41k internally fused w/ integral circuit breaker standard part a?dimension [inches (mm)] 2.475 (62.86) 3.25 (82.55) 3.45 (87.63) ??dimension [inches (mm)] 1.00 (25.4) 1.00 (25.4) 1.125 (28.58) type k foot mount - internally fused a and b dimensions for 60va & 75va models 3.00 (76.2) 2.106 (53.49) .830 (21.1) ??dim. a?dim. 2.50 (63.5) ??dim. primary v secondary v 60va 75va 120 24 4000-01l15k* 4000-01j15k* 240 24 4000-02l15k* 4000-02j15k* 277 24 4000-03l15k* 4000-03j15k* 480 24 4000-04l15k* 4000-04j15k* 120/208/240 24 4000-05l15k* 4000-05j15k* 208/240 24 4000-09l15k* 4000-09j15k* 208/240/480 24 4000-13j15k* 380/415 24 4000-51j15k* 575 24 4000-78j15k* 1.830 (46.48) 1.830 (46.48) 3.00 (76.2) 2.50 (63.5) type k foot mount - integral circuit breaker 1.830 (46.48) .218 dia (5.54) 2.0 (50.8) .218 (5.54) 2.50 (63.5) primary v secondary v 75va 120 24 4000-01j15k999 277 24 4000-03j15k999 208/240 24 4000-09j15k999 575 24 4000-78j15k999 120/208/240/480 24 4000-08j15k999 see table 2.106 (53.49) 3.562 (90.47) .22 (5.59) .187 dia (4.75) .750 (19.05) .062 (1.57) see table see table 2.106 (53.49) type g panel mount primary leads secondary leads voltage com 120 208 240 277 480 575 24 vac color black white red orange brown black/red gray blue yellow length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) strip length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) details regarding leads on standard models
210 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type bb same side termination - features quick connect terminals with line and load terminations on the same side of transformer. ?type ae laydown termination - features quick connect terminals with line and load terminations on the top of transformer. ?for agency approval, 60 & 75va transformers must have one of the following overcurrent protectors in series with the secondary winding: internal fuse, integral circuit breaker. any customer-supplied fusing or protection must be approved by the factory. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications terminals: standard male quick connects are .250?x .032?(6.35 x .81 mm). other available quick connects include .187?x .032 (4.75 x .81 mm) and .187?x .020?(4.75 x .51 mm). frequency: 50/60 hz. insulation class: ul class b (130?). weight: 60va ?35.2 oz. (997 g); 75va ?38.4 oz. (1087 g). 4000 series class ii ul 1585 transformer 60va -75va non-inherently energy limited secondary fusing required quick connect terminals file e87824 outline dimensions primary v secondary v 75va 120 24 4000-01j15ae999 208/240 24 4000-09j15ae999 standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. for type ae laydown termination, replace bb in above part numbers with ae. for more details about standard models see part numbering system table at beginning of transformer section in this catalog. all 75va standard models come with an integral circuit breaker. .187 dia (4.75) 3.562 (90.47) a?dim. .062 (1.57) .22 (5.59) .750 (19.05) ??dim. a?dim. .187 dia (4.75) internally fused w/ integral circuit breaker a?dimension [inches (mm)] 2.475 (62.86) 3.25 (82.55) ??dimension [inches (mm)] 1.00 (25.4) 1.00 (25.4) type bb same side termination type ae laydown termination - internally fused a and b dimensions for 60va & 75va models 3.00 (76.2) 2.10 (53.34) .830 (21.1) ??dim. a?dim. 2.50 (63.5) ??dim. 1. 0 (2.54) r .375 (9.53) primary v secondary v 60va 75va 120 24 4000-01l15bb* 4000-01j15bb* 240 24 4000-02l15bb* 4000-02j15bb* 277 24 4000-03l15bb* 4000-03j15bb* 480 24 4000-04l15bb* 4000-04j15bb* 120/208/240 24 4000-05l15bb* 4000-05j15bb* 208/240 24 4000-09l15bb* 4000-09j15bb* 208/240/480 24 4000-13j15bb* 380/415 24 4000-51j15bb* 575 24 4000-78j15bb* r .375 (9.53) 1.830 (46.48) 2.40 (61.0) .062 (1.57) 1.830 (46.48) 3.562 (90.47) 3.00 (76.2) .219 (5.56) 2.50 (63.5) 2.10 (53.34) type ae laydown termination - integral circuit breaker 1.830 (46.48) .830 (21.1) .062 (1.57) .187 dia (4.75) 1. 0 (2.54) r .375 (9.53) 3.562 (90.47) 3.00 (76.2) .219 (5.56) 2.50 (63.5) 2.40 (61.0)
211 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 (pdf rev. 4-04) specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?type k foot mount - features wire leads and a steel bracket welded to the bottom of the laminations for easy mounting. ?type bb same side termination - features quick connect terminals with line and load terminations on the same side of transformer. ?multiple voltage combinations are available. consult factory for availability. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. specifications wire size: all leads are 18 awg stranded 2/64?(.794 mm) insulation thickness. standard parts have 12?(305 mm) total length with 1/2?(12.7 mm) strip. terminals: standard male quick connects are .250?x .032?(6.35 x .81 mm). other available quick connects include .187?x .032 (4.75 x .81 mm) and .187?x .020?(4.75 x .51 mm). frequency: 50/60 hz. insulation class: ul class b (130?). weight: 60va ?36.8 oz. (1042 g); 100va ?80 oz. (2270 g); 150va ?83.2 oz. (2356 g). 4700 series ul 506 transformer 60va - 150va non-fused wire leads or quick connects file e102980 outline dimensions primary leads secondary leads voltage com 120 208 240 277 480 575 24 vac color black white red orange brown black/red gray blue yellow length [inches (mm)] 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) 12 (305) strip length [inches (mm)] 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) 0.5 (12.7) primary v secondary v 60va 100va 120 24 4700-81l15k999 120/208/240/480 24 4700-08k18k999 primary v secondary v 100va 150va 120 24 4700-01k18k* 4700-01z18k* 277 24 4700-03k18k* 4700-03z18k* 480 24 4700-04k18k* 4700-04z18k* 120/208/240/480 24 4700-08k18k* 208/240 24 4700-09k18k* 4700-09z18k* 208/230/460 24 4700-12k18k* 208/240/480 24 4700-13k18k* 400 24 4700-48k18k* 4700-48z18k* 575 24 4700-78k18k* 4700-78z18k* 460/575 24 4700-130k18k* 4700-130z18k* standard 999 models available partial listing of custom models * a three digit customer id suffix will be assigned by the factory. for more details about standard models see part numbering system table at beginning of transformer section in this catalog . .187 dia (4.75) see table .22 (5.59) .750 (19.05) type k foot mount 60va 3.562 (90.47) .062 (1.57) 3.00 (76.2) 2.106 (53.49) 2.50 (63.5) 2.475 (62.87) type k foot mount 100va 1.830 (46.48) see table 1. 0 0 (25.4) .187 x r. 375 (4.75 x 9.52) 2.313 (58.75) 3.125 (79.38) 2.53 (64.26) 3.125 (79.38) 3.75 (95.25) 2.165 (54.99) 1.25 (31.75) 2.875 (73.03) .075 (1.91)
212 products unlimited dimensions are shown for reference purposes only. dimensions are in inches over (millimeters) unless otherwise specified. catalog 1308242 issued 3-03 specifications and availability subject to change. www.tycoelectronics.com technical support: refer to inside back cover. features ?cover mounts on conventional 4?square box. ?all leads terminate in the box. ?leads are 8?(203.2 mm) long with 1/2?(12.7mm ) stripped) ?standard transformer is 40va class ii energy limited. other transformers are available. ?five secondary terminations (two are hot) for thermostat connection and #6-32 screw termination is standard. quick connects are optional. ?assembled with choice of 9100 or 9400 series relays. ?custom-built to meet customer requirements. users should thoroughly review the technical data before selecting a product part number. it is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. relay data @ 25c arrangements: 1 form a (spst-no) through 2 form c (dpdt), depending upon relay selected rating: 9100 series relay: 12 fla, 60 lra, 15a resistive @ 125vac; 6 fla, 36 lra, 15a resistive @ 240vac; 3/4 hp @ 125/250vac. 9400 series relay: 12 fla, 60 lra, 18a resistive @ 125vac; 8 fla, 48 lra, 18a resistive @ 240vac. specifications insulation class: ul class b (130?). duty cycle: continuous. weight: 32 oz. (909 g) approximately 57 series transformer relay for hvac applications file e113772 ordering information custom parts only. standard part numbers listed below are more likely to be available from stock. outline dimensions 57 series products are custom-built. your tyco electronics sales engineer will need to consult with the factory to develop a mo del meeting your needs. 4.25 (108) 4.25 (108) 1.88 (47.75) .50 (12.7) 2.00 (50.8) 2.56 (65.0) .18 7 (4.75) 1.25 (31.75) 3.375 (85.72) 3.375 (85.72) 1.25 (31.75) .50 (12.7) 2.00 (50.8) 2.56 (65.0) 1.25 (31.75) 1.25 (31.75) 4.25 (108) 4.25 (108) 3.375 (85.72) 3.375 (85.72) .18 7 (4.75) 2.25 (57.15) 1. 0 (25.4) 1.88 (47.75) .18 7 (4.75) .18 7 (4.75) 2.25 (57.15) 1. 0 (25.4) label label label label using 9100 series relay using 9400 series relay


▲Up To Search▲   

 
Price & Availability of 4000Y09AW18AE999

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X